100% Pass Quiz CDCS - Updated EXIN EPI Certified Data Centre Specialist Exam Duration
If you want to inspect the quality of our CDCS Study Dumps, you can download our free dumps from Exams4Collection and go through them. The unique questions and answers will definitely impress you with the information packed in them and it will help you to take a decision in their favor. The high quality and high pass rate has bbecome a reason for thousand of candidates to choose.
It is similar to the CDCS desktop-based software, with all the elements of the desktop practice exam. This mock exam can be accessed from any browser and does not require installation. The EXIN EPI Certified Data Centre Specialist (CDCS) questions in the mock test are the same as those in the real exam. And candidates will be able to take the web-based EXIN EPI Certified Data Centre Specialist (CDCS) practice test immediately through any operating system and browsers.
Correct CDCS Exam Duration & Leader in Qualification Exams & Pass-Sure Test CDCS Questions Fee
Cease to struggle and you cease to live. Only by continuous learning can we not be surpassed by others. Many people do not like to study and think that learning is a very vexing thing. This kind of cognition makes their careers stagnate. CDCS test question will change your perception. CDCS learning dumps aim to help students learn easily and effectively that has been developed over many years by many industry experts. With CDCS study tool, you no longer need to look at a drowsy textbook. You do not need to study day and night. With CDCS learning dumps, you only need to spend 20-30 hours on studying, and then you can easily pass the exam. At the same time, the language in CDCS test question is very simple and easy to understand. Even if you are a newcomer who has just entered the industry, you can learn all the knowledge points without any obstacles. We believe that CDCS study tool will make you fall in love with learning. Come and buy it now.
EXIN EPI Certified Data Centre Specialist Sample Questions (Q35-Q40):
NEW QUESTION # 35
The humidity in the computer room has changed from about 50% down to 35% Relative Humidity (RH).
What influence does this have on Electrostatic Discharge (ESD)?
- A. ESD levels will go down
- B. No influence as long as the temperature is at approximately 20°C/77°F
- C. ESD levels will go up
- D. Relative humidity has no influence on ESD
Answer: C
Explanation:
As relative humidity decreases, Electrostatic Discharge (ESD) risks increase. Lower humidity levels reduce the amount of moisture in the air, which normally helps dissipate static charges. When the humidity drops from 50% to 35%, the likelihood of static electricity accumulating on surfaces rises, leading to a higher potential for ESD incidents that could damage sensitive IT equipment.
Detailed Explanation:
ESD events are more common in dry environments because there is less atmospheric moisture to neutralize electrical charges. Maintaining relative humidity above 40% helps minimize the risk of ESD, which is why data centers often control humidity levels tightly to protect equipment from static discharge that could cause hardware failures or data loss.
EPI Data Center Specialist References:
EPI data center best practices stress the importance of maintaining stable humidity levels to prevent ESD, particularly in computer rooms. Recommended humidity ranges are typically above 40% to prevent conditions that would foster static buildup.
NEW QUESTION # 36
You are allowed to use a calculator for this question.
A computer room has a net volume of approximately 2,500 m³ / 88,287 ft³.
The temperature is 20 °C / 68 °F.
The required design concentration is 7%.
The S-Factor is 0.1359 (metric) / 1.885 (imperial).
Calculate the amount of gas required for this computer room based on FM200. What is the correct weight?
- A. Approximately 1,390 kg / 3,000 lbs
- B. Approximately 410 kg / 900 lbs
- C. Approximately 1,640 kg / 3,600 lbs
- D. Approximately 820 kg / 1,800 lbs
Answer: D
Explanation:
The amount of FM200 gas required can be calculated using the formula:
Weight of Gas=Net Volume×Design Concentration×S-Factor ext{Weight of Gas} = ext{Net Volume} imes ext{Design Concentration} imes ext{S-Factor}Weight of Gas=Net Volume×Design Concentration×S-Factor Using metric units:
Net Volume: 2,500 m³
Design Concentration: 7% (or 0.07)
S-Factor: 0.1359
Calculation:
2,500 m3×0.07×0.1359=821.325 kg2,500 , ext{m}